Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Int. j. cardiovasc. sci. (Impr.) ; 36: e20210040, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1421770

ABSTRACT

Abstract Takayasu arteritis (TA) is a rare type of vasculitis that affects mainly the aorta and its major branches. It is highly similar to giant cell arteritis (GCA), and differentiation between them may not be achieved even by histological examination. Arterial hypertension is typical of TA and is caused by stenosis of the renal arteries. Here we report the case of a 59-year-old woman, with a history of dyslipidemia and anemia, seen in the Internal Medicine department for resistant hypertension. Evaluation of secondary causes led to stenosis of the renal arteries. Assessment of target organ involvement was performed by computed tomography angiograph which revealed ectasia of the aortic arch and ascending aorta, tortuous course of the brachiocephalic trunk and the proximal portion of the right common carotid artery; positron-emission tomography which showed diffuse increased uptake in the ascending aorta, compatible with large vessels vasculitis. The patient was submitted to aortic valve replacement with a biological prosthesis combined with myocardial revascularization (Bentall-De Bono procedure). Aortic biopsy specimens showed anatomical and pathological features of GCA and TA. Due to persistently uncontrolled hypertension, prednisone 60 mg was initiated,with significant improvement in patient's condition.

4.
Radiol. bras ; 55(3): 156-160, May-june 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1387084

ABSTRACT

Abstract Objective: To compare the degree of coronary stenosis (≥ 50% luminal narrowing) determined by coronary computed tomography angiography (CCTA) with that determined by invasive coronary angiography (ICA), using segment-by-segment analysis. Materials and Methods: This was a retrospective study of the records of patients who underwent CCTA and ICA between January 2014 and June 2018 at a general hospital in Brazil. Receiver operating characteristic curve analysis was applied, and the areas under the curve were used in order to assess the overall accuracy of the methods. Results: The degree of coronary stenosis was evaluated in a total of 844 arterial segments. The diagnostic performance of CCTA was good, with a sensitivity of 82.3%, a specificity of 96.4%, and a negative predictive value of 97.7% (95% CI: 96.5-98.5). In the segment-by-segment analysis, CCTA had excellent accuracy for the left main coronary artery and for other segments. Conclusion: In clinical practice at general hospitals, CCTA appears to have diagnostic performance comparable to that of ICA.


Resumo Objetivo: O objetivo do estudo é comparar os graus de estenose coronariana (≥ 50% de redução luminal) determinados pela tomografia computadorizada e pelo cateterismo, utilizando uma análise segmento a segmento. Materiais e Métodos: Estudo retrospectivo conduzido em pacientes que foram submetidos a tomografia computadorizada e a cateterismo, de janeiro de 2014 a junho de 2018, em um hospital geral. A análise da curva característica de operação do receptor foi utilizada para a análise da acurácia. Resultados: Na avaliação dos vasos, em um total de 844 segmentos, o desempenho da tomografia computadorizada foi bom, com sensibilidade de 82,3%, especificidade de 96,4% e valor preditivo negativo de 97,7% (IC 95%: 96,5-98,5). Na análise segmento a segmento, o tronco da coronária esquerda, assim como outros segmentos, apresentaram excelente acurácia. Conclusão: A tomografia computadorizada mostrou bom desempenho diagnóstico quando comparada com o cateterismo na prática diária de um hospital geral.

5.
Arq. bras. cardiol ; 118(3): 607-613, mar. 2022. tab
Article in English, Portuguese | LILACS | ID: biblio-1364344

ABSTRACT

Resumo Fundamento A ventriculografia esquerda é um método invasivo para avaliar a função sistólica do ventrículo esquerdo. Depois do advento de métodos não invasivos, o seu uso tem sido questionado por resultar em algum risco para o paciente. Objetivos Avaliar quais fatores associam-se independentemente com a decisão de realizar ventriculografia em pacientes com doença arterial coronariana. Métodos Tratou-se de um estudo analítico, retrospectivo, avaliando prontuários eletrônicos e banco de dados e comparando 21 variáveis de interesse pré-definidas entre pacientes submetidos a cineangiocoronariografia. Foi considerado significante p < 0,05. Resultados Avaliamos 600 pacientes consecutivos, e a ventriculografia esquerda foi realizada na maioria dos pacientes submetidos a uma cineangiocoronariografia (54%). Depois da análise multivariada, os pacientes com síndromes coronarianas crônicas ( odds ratio [OR] 1,72; intervalo de confiança de 95% [IC 95%]: 1,20-2,46; p < 0,01) tiveram maior chance de serem submetidos ao procedimento. Os pacientes com função ventricular conhecida (OR = 0,58; IC 95%: 0,40-0,85; p < 0,01), os revascularizados (OR 0,31; IC 95% 0,14-0,69; p < 0,01), os hipertensos (OR 0,58; IC 95%: 0,36-0,94; p = 0,02) e aqueles com maiores valores de creatinina (OR 0,42; IC 95% 0,26-0,69; p < 0,01) tiveram maior chance de não realizar ventriculografia. Conclusões Nos pacientes submetidos a cineangiocoronariografia, o diagnóstico de síndrome coronariana crônica associou-se de modo independente com uma maior realização da técnica, enquanto ter a função ventricular previamente conhecida, ser hipertenso, ter sido submetido a revascularização cirúrgica prévia e ter valores de creatinina mais elevados associaram-se a uma maior chance de não realizar o método.


Abstract Background Left ventriculography is an invasive method for assessment of left ventricular systolic function. Since the advent of noninvasive methods, its use has been questioned, as it carries some risk to the patient. Objective To assess which factors are independently associated with the decision to perform ventriculography in patients with coronary artery disease. Methods Analytical, retrospective, database review study of electronic medical records comparing 21 predefined variables of interest among patients undergoing coronary angiography. P-values <0.05 were considered significant. Results We evaluated 600 consecutive patients undergoing coronary angiography. Left ventriculography was performed in the majority of cases (54%). After multivariate analysis, patients with chronic coronary syndrome (OR 1.72; 95% CI: 1.20-2.46; p < 0.01) were more likely to undergo the procedure. Patients with known ventricular function (OR 0.58; 95% CI: 0.40-0.85; p < 0.01); those with a history of CABG (OR 0.31; 95% CI: 0.14-0.69; p < 0.01) or hypertension (OR 0.58; 95% CI: 0.36-0.94; p = 0.02); and those with higher creatinine levels (OR 0.42; 95% CI: 0.26-0.69; p < 0.01) had greater odds of not undergoing ventriculography. Conclusions In patients undergoing coronary angiography, a diagnosis of chronic coronary syndrome was independently associated with greater likelihood of left ventriculography, while having previously determined ventricular function, a history of hypertension or CABG, and higher creatinine levels were associated with a decreased likelihood of undergoing this procedure.


Subject(s)
Humans , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Retrospective Studies , Ventricular Function, Left , Coronary Angiography , Heart
7.
Arq. bras. cardiol ; 118(2): 478-485, 2022. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1364331

ABSTRACT

Resumo Fundamento A relação direta entre a doença arterial coronariana (DAC) e o câncer de pulmão não é bem conhecida. Objetivo Investigar a associação entre a gravidade anatômica da DAC e do câncer de pulmão. Métodos Trezentos pacientes, incluindo 75 recém-diagnosticados com câncer de pulmão e 225 pacientes correspondentes sem câncer, foram submetidos à angiografia coronária durante a internação, sem intervenção coronária percutânea (ICP) prévia nem enxerto de bypass da artéria coronária (CABG). O escore SYNTAX foi utilizado para avaliar a gravidade da DAC. Uma pontuação alta no escore foi definida como > 15 (o maior quartil do escore SYNTAX). O teste de tendência de Cochran-Armitage foi utilizado para verificar a distribuição dos escores dos pacientes. Uma análise de regressão logística foi utilizada para avaliar a associação entre a gravidade da DAC e o câncer de pulmão. Os valores de p foram estabelecidos quando o nível de significância era 5%. Resultados A tendência de distribuição dos escores SYNTAX dos pacientes por quartis foi diferente entre aqueles com câncer de pulmão e controles (do quartil mais baixo ao mais alto: 20,0%; 20,0%; 24,0%; 36,0% vs. 26,7%; 26,2%; 25,8%; 21,3%; p=0,022). A pontuação no escore SYNTAX foi mais alta em pacientes com câncer do que nos pacientes controle (36,0% vs. 21,3%, p=0,011).O maior quartil do escore demonstrou mais riscos de desenvolver câncer de pulmão em comparação ao quartil mais baixo (OR: 2.250, IC95%: 1.077 a 4.699 ; P -trend= 0,016). Após ajustes, os pacientes no maior quartil do escore SYNTAX tinham mais risco de desenvolver câncer de pulmão (OR: 2.1o49, IC95%: 1.008 a 4.584; P -trend= 0,028). Pacientes com escores SYNTAX alto (> 15) tinham 1.985 mais chances de ter câncer de pulmão (IC95%: 1.105-3.563, P= 0,022). Conclusão A gravidade anatômica da DAC está associada ao risco de câncer de pulmão, o que indica que um rastreamento completo deste tipo de câncer possa ser mais significativo entre pacientes com DAC.


Abstract Background The direct relationship between coronary artery disease (CAD) and lung cancer is not well known. Objective To investigate the association between the anatomical severity of CAD and lung cancer. Methods Three-hundred study patients, including 75 recently diagnosed lung cancer patients and 225 matched non-cancer patients, underwent coronary angiography during hospitalization without previous percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). The SYNTAX score (SXscore) was used to assess the severity of CAD. A high SXscore (SXhigh) grade was defined as SXscore > 15 (the highest quartile of the SXscore). The Cochran-Armitage test for trend was used to assess the distribution of patients' SXscores. Logistic regression analysis was used to assess the association between the severity of CAD and lung cancer. P-values were set when significance level was 5%. Results The distribution trend of patients' SXscore by quartiles was different between lung cancer patients and control patients (from the lowest to the highest quartile: 20.0%, 20.0%, 24.0%, 36.0% vs. 26.7%, 26.2%, 25.8%, 21.3%, p=0.022). The SX high rate was higher in lung cancer patients than in control patients (36.0% vs. 21.3%, p=0.011).The highest quartile of the SXscore showed higher risk of lung cancer in comparison to the lowest quartile (OR: 2,250, 95%CI: 1,077 to 4,699 ; P-trend= 0.016). After adjustment, patients in the highest quartile of the SXscore had higher risk of lung cancer (OR: 2,149, 95%CI: 1,008 to 4,584; P-trend= 0.028). Patients with high SXscore (> 15) had 1,985 times more chances of having lung cancer (95%CI: 1,105-3,563, P= 0.022). Conclusions The anatomical severity of CAD is associated with the risk of lung cancer, which indicates that a thorough lung cancer screening may be significant among severe CAD patients.


Subject(s)
Humans , Coronary Artery Disease/surgery , Coronary Artery Disease/diagnostic imaging , Percutaneous Coronary Intervention , Severity of Illness Index , Cross-Sectional Studies , Coronary Angiography , Early Detection of Cancer , Lung Neoplasms/diagnostic imaging
8.
Radiol. bras ; 54(4): 261-264, July-Aug. 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1287756

ABSTRACT

Abstract Almost two decades ago, it became possible to use coronary computed tomography for the noninvasive assessment of the coronary arteries. That is an extremely accurate method for detecting or excluding coronary artery disease, even the subclinical forms. This pictorial essay aims to show the main imaging findings in 47 coronary computed tomography scans acquired at a general hospital between January 2014 and June 2018. The most common findings were atheromatous plaques (in 87%) and stents (in 34%). There were also incidental findings, not directly related to coronary artery disease, such as pulmonary nodules and aortic stenosis.


Resumo Há quase duas décadas, tornou-se possível a avaliação não invasiva das coronárias por meio da angiotomografia. Esta é bastante importante para excluir ou detectar doença arterial coronariana, mesmo que subclínica. Este ensaio tem o objetivo de mostrar os principais achados de imagem em 47 angiotomografias realizadas de janeiro de 2014 a junho de 2018 em um hospital geral. Os achados mais frequentes foram a presença de placas ateromatosas (87%) e stents (34%). Além desses, houve também achados incidentais não relacionados diretamente com doença arterial coronariana, como nódulos pulmonares e estenose aórtica.

9.
Arq. bras. oftalmol ; 84(4): 383-386, July-Aug. 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1285292

ABSTRACT

ABSTRACT We conducted retinal neovascularization under subfoveal fibrotic nodule for Coats disease by using optic coherence tomography-angiography before and after ranibizumab treatment. Our patient was an 8-year-old boy who was referred with suspicious left retinal mass. His visual acuity was 20/400 in the left eye and 20/20 in the right eye at the time of admission. Posterior segment evaluation of the left eye revealed telengiectatic vessels at the inferotemporal region of the peripheral retina with hard exudates around the optic disc and macula typical for Coats disease. His optic coherence tomography revealed a subfoveal fibrotic nodule after ranibizumab injections and laser photocoagulation treatment. The optic coherence tomography-angiography results revealed neovascularization under the subfoveal nodule at the superficial vascular complex layer. After 3 intravitreal ranibizumab injections, his neovascularization regressed on optic coherence tomography-angiography and his visual acuity improved. To the best of our knowledge, this is the first report demonstrating neovascularization under the subfoveal fibrotic nodule in Coats disease on the basis of comparative with the help of optic coherence tomography-angiography before and after the treatment.


RESUMO Demonstramos uma neovascularização da retina sob o nódulo fibrótico subfoveal na doença de Coats com a ajuda da Angiotomografia de Coerência Óptica (OCT-A) antes e após o tratamento com ranibizumabe. Paciente do sexo masculino de 8 anos foi encaminhado com suspeita de massa retiniana no olho esquerdo. A acuidade visual foi de 20/400 no olho esquerdo e de 20/20 no olho direito. A avaliação do segmento posterior do olho esquerdo revelou vasos telengiectáticos na região inferotemporal da retina periférica e exsudados duros em torno do disco óptico e mácula típica da doença de Coats. A angiotomografia de coerência óptica apresentou nódulo fibrótico subfoveal após injeções de ranibizumabe e tratamento com fotocoagulação a laser. A angiotomografia de coerência óptica mostrou neovascularização sob o nódulo subfoveal na camada superficial do complexo vascular. Após três injeções de ranibizumabe intravítreo, a neovascularização regrediu na angiografia por tomografia de coerência óptica e a acuidade visual melhorou. onde sabemos, este é o primeiro relato a mostrar neovascularização sob nódulo fibrótico subfoveal na Doença de Coats com a ajuda da angiografia por tomografia de coerência óptica antes e após o tratamento.

11.
Arq. bras. cardiol ; 117(1): 89-90, July. 2021.
Article in Portuguese | LILACS | ID: biblio-1285234

ABSTRACT

Resumo A fístula da artéria coronária é uma anormalidade anatômica rara das artérias coronárias que afeta 0,002% da população geral e representa 14% de todas as anomalias das artérias coronárias. A sua relevância clínica concentra-se principalmente no mecanismo do fenômeno do roubo coronário, que causa isquemia funcional do miocárdio, mesmo na ausência de estenose; portanto, angina e dispneia aos esforços são sintomas comuns. A abordagem diagnóstica sugerida é orientada pelos sintomas dos pacientes e consiste em uma série de exames instrumentais, como ECG, teste de esteira, ecocardiografia, tomografia computadorizada, ressonância magnética cardíaca e angiografia coronária. Nos casos onde não é um achado acidental, a angiografia coronária é necessária para o planejamento terapêutico otimizado. As pequenas fístulas geralmente são assintomáticas e o prognóstico é excelente se forem tratadas medicamente com acompanhamento clínico e ecocardiografia no período de 2 a 5 anos. As fístulas grandes/gigantes e sintomáticas, ao contrário, devem ser submetidas a fechamento invasivo, por via transcateter ou ligadura cirúrgica, cujos resultados são equivalentes no acompanhamento de longo prazo. A profilaxia antibiótica para a prevenção da endocardite bacteriana é recomendada para todos os pacientes com fístulas da artéria coronária submetidos a procedimentos dentários, gastrointestinais ou urológicos. O acompanhamento ao longo da vida é sempre essencial para garantir que o paciente não sofra progressão da doença ou outras complicações cardíacas.


Abstract Coronary artery fistula is a rare anatomic abnormality of the coronary arteries that affects 0.002% of the general population and represents 14% of all anomalies of coronary arteries. Its clinical relevance focuses mainly on the mechanism of the coronary steal phenomenon, causing myocardial functional ischemia, even in the absence of stenosis; therefore, angina and effort dyspnea are common symptoms. The suggested diagnostic approach is driven by patients' symptoms, and it consists of a number of instrumental examinations like ECG, treadmill test, echocardiography, computed tomography scan, cardiac magnetic resonance, and coronary angiography. If it is not an incidental finding, coronary angiography is required in view of optimal therapeutic planning. Small fistulae are usually asymptomatic, and prognosis is excellent if they are managed medically with clinical follow-up and echocardiography every 2 to 5 years. Large/giant, symptomatic fistulae, on the contrary, should undergo invasive closure, via either transcatheter approach or surgical ligation, whose results are equivalent at long-term follow-up. Antibiotic prophylaxis for prevention of bacterial endocarditis is recommended in all patients with coronary artery fistulae who undergo dental, gastrointestinal, or urological procedures. Life-long follow-up is always essential to ensure that the patient does not undergo progression of the disease or further cardiac complications.


Subject(s)
Humans , Coronary Artery Disease/diagnostic imaging , Coronary Vessel Anomalies , Fistula , Coronary Angiography
14.
Arq. bras. oftalmol ; 84(1): 2-10, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1153103

ABSTRACT

ABSTRACT Purpose: The aim of the study is to evaluate the retinal and choroidal microvascular changes via optical coherence tomography angiography in patients who received hydroxy­chloroquine. Methods: In total, 28 eyes of 28 patients (24 females, and 4 males) receiving treatment with hydroxy­chloroquine were assessed in this cross-sectional cohort study (hydroxychloroquine group). The high-and low-risk groups consisted of patients receiving hydroxychloroquine for ≥5 years (14 eyes of 28 patients) and <5 years (14 eyes of 28 patients), respectively. A total of 28 age- and gender-matched volunteers were enrolled as the control group. The macular flow area (superficial, deep, and choriocapillaris), superficial and deep vessel density, foveal avascular zone area, central foveal thickness, and subfoveal choroidal thickness parameters were measured by optical coherence tomography angiography. Results: The mean age of the 28 patients who received hydroxychloroquine and the 28 age-matched controls was 45.5 ± 11.1 years (range: 29-70 years) and 44.5 ± 13.9 years (range: 28-70 years), respectively. In patients who received hydroxychloroquine, the values for the superficial, deep, and choriocapillaris macular flow areas were 13.578 ± 0.30, 13.196 ± 0.31, and 17.617 ± 0.42, respectively. In controls, these values were 16.407 ± 0.95, 13.857 ± 0.31, and 18.975 ± 0.76, respectively (p<0.05 for all). The superficial, deep, and cho­riocapillaris flow areas were significantly smaller in patients who received hydroxychloroquine than those in controls (p<0.05 for all). Superficial and deep vessel densities were significantly reduced in patients who received hydroxychlo­roquine in all regions (i.e., foveal, parafoveal, temporal, superior, nasal, and inferior) (p<0.05 for all). Moreover, significant difference was observed between the groups in the foveal avascular zone area (superficial and deep), central foveal thickness, and subfoveal choroidal thickness (p<0.05 for all). Conclusions: Retinochoroidal microvascular flow and vessel density of the macular area were significantly decreased in patients who received hydroxychloroquine. Hy­droxychloroquine may damage the retinochoroidal mi­cro­vascular architecture. Optical coherence tomography angiography may contribute to the early detection of hy­dro­xychloroquine-induced retinal toxicity.


RESUMO Objetivo: O objetivo do estudo foi de avaliar as alterações microvasculares da retina e da coroide em pacientes sob hidroxicloroquina, através da angiografia por tomografia de coerência óptica. Métodos: Este é um estudo transversal de coorte que avaliou um total de 28 olhos de 28 pacientes (24 mulheres e 4 homens) submetidos a tratamento com hidroxicloroquina (grupo da hidroxicloroquina). Catorze olhos de 28 pacientes em uso de hidroxicloroquina por mais de 5 anos foram definidos como sendo o grupo de alto risco, ao passo que o grupo de baixo risco consistiu em 14 olhos de 28 pacientes em uso de hidroxicloroquina por menos de 5 anos. Foram ainda incluídos 28 voluntários como grupo de controle, pareados por idade e sexo. Através de angiografia por tomografia de coerência óptica, foram medidos os seguintes parâmetros: área do fluxo macular (superficial, profundo e coriocapilar), densi­dade vascular superficial e profunda, área da zona avascular foveal e espessura da coroide subfoveal. Resultados: Foram recrutados para o estudo um total de 28 pacientes sob tratamento com hidroxicloroquina, com idade média de 45,5 ± 11,1 (29-70) anos, e 28 membros do grupo de controle, pareados por idade e sexo, com idade média de 44,5 ± 13,9 (28-70) anos. As áreas superficial, profunda e coriocapilar do fluxo macular foram respectivamente de 13,578 ± 0,30, 13,196 ± 0,31 e 17,617 ± 0,42 nos pacientes em tratamento com hidroxicloroquina e, respectivamente de 16,407 ± 0,95, 13,857 ± 0,31 e 18,975 ± 0,76 no grupo de controle (p<0,05 para todos os valores). As três medições de área do fluxo macular foram significativamente menores nos pacientes em uso de hidroxicloroquina em comparação com os indivíduos do grupo de controle (p<0,05 para todos os valores). As densidades vasculares superficial e profunda mostraram-se significativamente reduzidas em todas as regiões (foveal, parafoveal, temporal, superior, nasal e inferior) nos pacientes em uso de hidroxicloroquina (p<0,05 para todos os valores). Finalmente, também foi observada uma diferença significativa entre os grupos em relação à área da zona avascular foveal (superficial e profunda), à espessura foveal central e à espessura da coroide subfoveal (p<0,05 para todos os valores). Conclusão: O fluxo microvascular retinocoroidal e a densidade vascular da área macular mostraram-se significativamente diminuídos nos pacientes sob hidroxicloroquina. Este fármaco pode danificar a arquitetura microvascular retinocoroidal e a angiografia por tomografia de coerência óptica pode contribuir para a detecção precoce da toxicidade retiniana induzida pela hidroxicloroquina.


Subject(s)
Humans , Adult , Middle Aged , Aged , Tomography, Optical Coherence , Hydroxychloroquine , Retinal Vessels/diagnostic imaging , Fluorescein Angiography , Visual Acuity , Cross-Sectional Studies , Choroid/diagnostic imaging , Hydroxychloroquine/adverse effects
15.
Arq. bras. oftalmol ; 83(6): 473-477, Nov.-Dec. 2020. tab, graf
Article in English | LILACS | ID: biblio-1153078

ABSTRACT

ABSTRACT Purpose: To describe the findings on optical coherence tomography angiography associated with Alport syndrome. Methods: Descriptive study from a referral ophthalmology service (Hospital Evangélico de Vila Velha, Brazil). Patients diagnosed with Alport syndrome were included. Results: The study group consisted of four patients (one female and three males) diagnosed with Alport syndrome. Visual acuity in the worst eye was between 20/40 and 20/60. All male patients had anterior lenticonus on biomicroscopy. The observed retinal findings included dots and flecks and pigmentary changes in the macula. On optical coherence tomography angiography, the inner retinal layers of all patients displayed thinning (especially in the temporal quadrant of the macula) and an increase in the foveal avascular zone. A thick choroid was observed in both eyes of the two youngest patients. Conclusions: In patients with Alport syndrome, the inner retinal layers suffer changes due to type IV collagen mutations. Optical coherence tomography angiography makes it possible to visualize and document these findings, making it a useful tool in the detection of early retinal findings associated with Alport syndrome.


RESUMO Objetivos: Descrever os achados na angiografia por tomografia de coerência óptica associada à síndrome de Alport. Métodos: Estudo descritivo de um serviço de referência em Oftalmologia (Hospital Evangélico de Vila Velha, Brasil). Os pacientes diagnosticados com síndrome de Alport, foram incluídos. Resultados: O grupo de estudo foi composto por quatro pacientes (um feminino e três homens) com diagnóstico de síndrome de Alport. A acuidade visual no pior olho estava entre 20/40 a 20/60. Todos os pacientes do sexo masculino apresentaram lenticone anterior à biomiscroscopia. Os achados da retina observados incluíram pontos e manchas e alterações pigmentares na mácula. Na angiotomografia de coerência óptica, as camadas internas da retina de todos os pacientes apresentaram afinamento (especialmente na região temporal da mácula) e aumento da zona avascular foveal. Uma coroide espessa foi observada em ambos os olhos dos dois pacientes mais jovens. Conclusões: Em pacientes com síndrome de Alport, as camadas internas da retina sofrem alterações devido à mutação do colágeno tipo IV. A angiotomografia de coerência óptica permite visualizar esses achados, tornando-o uma ferramenta útil na detecção de achados iniciais da retina associados à síndrome de Alport.


Subject(s)
Humans , Male , Female , Macula Lutea , Nephritis, Hereditary , Retinal Vessels , Brazil , Fluorescein Angiography , Tomography, Optical Coherence , Nephritis, Hereditary/diagnostic imaging
17.
Arq. bras. cardiol ; 115(3): 503-512, out. 2020. tab, graf
Article in English, Portuguese | LILACS, SES-SP | ID: biblio-1131314

ABSTRACT

Resumo Fundamento O grau de fluxo TIMI e a contagem quadro a quadro TIMI corrigida (CTFC) são métodos amplamente utilizados para avaliar o fluxo sanguíneo coronariano angiográfico. A medição do fluxo sanguíneo coronariano (FSC) na coronariografia (CAG) padrão despertou grande interesse recentemente, tentando combinar o conceito de CTFC com novos métodos para pós-angioplastia e avaliação da síndrome cardíaca X. Além disso, o fluxo coronariano lento é considerado um critério importante para a angina microvascular. Objetivo Explorar uma nova abordagem de medição angiográfica quantitativa do FSC com base na detecção densitométrica de contraste na CAG offline, usando um software acessível para obter uma avaliação mais precisa e confiável do FSC. Métodos Trinta pacientes foram estudados e divididos em 2 grupos: fluxo sanguíneo coronariano normal (FN) e fluxo sanguíneo coronariano lento (FL), de acordo com a definição da CTFC. O MD foi aplicado à amostra do estudo para diferenciar entre FN e FL. A estatística não paramétrica foi usada para avaliar diferenças entre os grupos com p<0,05. Resultados O valor de referência normal do MD obtido para o fluxo sanguíneo coronariano foi de 9 [5-10] quadros. Os grupos FN vs. FL foi comparado e expresso como mediana [intervalo interquartil], para a artéria descendente anterior esquerda: 10 [7-11] vs. 21 [8-33]; p=0,016; artéria circunflexa: 9 [4-13] vs. 14 [11-30]; p=0,012 e artéria coronária direita: 5 [3-11] vs. 13 [8-26]; p=0,009. Conclusão O MD mostrou a viabilidade de medir o fluxo sanguíneo coronariano com precisão, consistência e reprodutibilidade em um angiograma coronariano padrão, mostrando a capacidade adicional de diferenciar FN de FL em pacientes com dor precordial e artérias coronárias normais. (Arq Bras Cardiol. 2020; 115(3):503-512)


Abstract Background TIMI flow grade and corrected TIMI frame count (CTFC) are widely used methods to evaluate angiographic coronary blood flow. Measurement of coronary blood flow (CBF) on standard coronary angiography (CAG) has aroused great interest recently, trying to combine the CTFC concept with new methods for post-angioplasty and for cardiac syndrome X assessment. Additionally, coronary slow flow it is now considered a major criterion for microvascular angina. Objective Explore a new approach of quantitative angiographic measurement of CBF based on densitometric contrast detection in CAG off-line, using an accessible software to obtain a more precise and reliable CBF assessment. Methods Thirty patients were studied and divided in 2 groups, normal coronary blood flow (NF) and slow coronary blood flow (SF), according to CTFC definition. The DM was applied to the study sample to differentiate between NF and SF. Non-parametric statistics was used to assess differences between groups at p<0.05. Results The DM normal reference value obtained for coronary blood flow was 9 [5-10] frames. NF vs SF group were compared and expressed as median [interquartile range], for the left anterior descending: 10 [7-11] vs 21 [8-33];p= 0.016; circumflex: 9 [4-13] vs 14 [11-30]; p= 0.012 and right coronary artery: 5 [3-11] vs 13 [8-26]; p=0.009. Conclusion The DM showed the feasibility of measuring coronary blood flow with precision, consistency and reproducible in a standard coronary angiogram, showing the additional capability to differentiate between NF and SF in chest pain patients with normal coronary arteries. (Arq Bras Cardiol. 2020; 115(3):503-512)


Subject(s)
Humans , Microvascular Angina , Coronary Circulation , Blood Flow Velocity , Coronary Angiography , Hemodynamics
18.
Arq. bras. cardiol ; 115(4): 680-687, out. 2020. graf
Article in Portuguese | SES-SP, LILACS | ID: biblio-1131356

ABSTRACT

Resumo Fundamento O implante valvar aórtico percutâneo (TAVR, do inglês Transcatheter Aortic Valve Replacement) reduz a mortalidade de pacientes portadores de estenose aórtica grave. O conhecimento da distribuição da pressão e tensão de cisalhamento na parede aórtica pode ajudar na identificação de regiões críticas, onde o processo de remodelamento aórtico pode ocorrer. Neste trabalho é apresentado um estudo de simulação computacional da influência do posicionamento do orifício valvar protético na hemodinâmica na raiz de aorta e segmento ascendente. Objetivos A presente análise apresenta um estudo da variação do padrão de fluxo devido a alterações no ângulo do orifício valvar. Métodos Um modelo tridimensional foi gerado a partir do exame de angiotomografia computadorizada da aorta de um paciente que foi submetido ao procedimento de TAVR. Diferentes vazões de fluxo foram impostas através do orifício valvar. Resultados Pequenas variações no ângulo de inclinação causaram mudanças no padrão de fluxo, com deslocamento na posição dos vórtices, na distribuição de pressão e no local de alta tensão cisalhante na parede aórtica. Conclusão Essas características hemodinâmicas podem ser importantes no processo de remodelamento aórtico e distribuição de tensão, além de auxiliar, em um futuro próximo, a otimização do posicionamento da prótese valvar percutânea. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Backgroud Transcatheter aortic valve replacement (TAVR) can reduce mortality among patients with aortic stenosis. Knowledge of pressure distribution and shear stress at the aortic wall may help identify critical regions, where aortic remodeling process may occur. Here a numerical simulation study of the influence of positioning of the prosthetic valve orifice on the flow field is presented. Objective The present analysis provides a perspective of great variance on flow behavior due only to angle changes. Methods A 3D model was generated from computed tomography angiography of a patient who had undergone a TAVR. Different mass flow rates were imposed at the inlet valve. Results Small variations of the tilt angle could modify the nature of the flow, displacing the position of the vortices, and altering the prerssure distribution and the location of high wall shear stress. Conclusion These hemodynamic features may be relevant in the aortic remodeling process and distribution of the stress mapping and could help, in the near future, the optimization of the percutaneous prosthesis implantation. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Subject(s)
Humans , Aortic Valve Stenosis/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement/adverse effects , Aorta , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Computed Tomography Angiography , Hemodynamics
19.
Int. j. cardiovasc. sci. (Impr.) ; 33(5): 591-596, Sept.-Oct. 2020. graf
Article in English | LILACS | ID: biblio-1134412

ABSTRACT

Abstract Myocardial bypass (MB) is known to have scientific relevance and is present in several studies with great statistical significance regarding its clinical manifestations and complications. There are still questions about MB in its relationship with heart disease and repercussion in life-threatening conditions. We present a case report of a MB in the left anterior descending coronary artery, whose objective is to identify this rare congenital anomaly and to highlight the patient's clinical outcome in order to elicit greater contributions about the presence of this variant in the emergency room, its diagnosis by angiography and therapeutic management.


Subject(s)
Humans , Female , Middle Aged , Myocardial Bridging/therapy , Myocardial Bridging/diagnostic imaging , Coronary Angiography/methods , Emergency Service, Hospital , Myocardial Bridging/complications , Cardiac Electrophysiology/methods , Ischemia
20.
Rev. bras. ortop ; 55(1): 70-74, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1092675

ABSTRACT

Abstract Objective The aim of the present study is to evaluate the artery of Adamkiewicz by multidetector computed tomography angiography (MCTA) in a Brazilian population. Methods Two independent observers evaluated 86 coronary MCTA examinations. The variables studied included the identification of the artery of Adamkiewicz at its origin level, and its entry side in the spine. Results The artery of Adamkiewicz was detected in 71 (82.5%) examinations. The origin level was identified between the 9th and 11th thoracic vertebrae (T9 and T11) in 56 (79.2%) patients. In 65 (91.5%) patients, the artery was on the left side. The identification of the artery of Adamkiewicz using MCTA showed high reproducibility. Conclusions Our results were consistent with the literature regarding the identification of the artery of Adamkiewicz using MCTA, suggesting that this technique should be considered as an option to recognize this structure. In addition, we found that the distribution of the artery of Adamkiewicz in the Brazilian population is similar to that of other populations, that is, its most common origin is at the left side, between the 8th and 12th thoracic vertebrae (T8-T12).


Resumo Objetivo Avaliar a artéria de Adamkiewicz por angiotomografia computadorizada por multidetectores (ATCM) em uma população brasileira. Métodos Dois observadores independentes avaliaram 86 exames de ACTM. As variáveis estudadas incluíram a identificação da artéria de Adamkiewicz no nível de origem e o lado de entrada da artéria na coluna vertebral. Resultados A artéria de Adamkiewicz foi identificada em 71 (82,5%) exames. O nível de origem foi identificado entre a 9a e a 11a vértebras torácicas (T9 e T11) em 56 (79,2%) pacientes. Em 65 (91,5%) pacientes, a artéria foi identificada no lado esquerdo. A identificação da artéria de Adamkiewicz usando ACTM mostrou elevada reprodutibilidade. Conclusões Obtivemos resultados consistentes com os da literatura prévia quanto à identificação da artéria de Adamkiewicz utilizando angiotomografia computadorizada por multidetectores. Nossos resultados sugerem que a ATCM pode ser considerada como uma opção para identificar a artéria de Adamkiewicz. Além disso, encontramos uma distribuição da artéria de Adamkiewicz na população brasileira semelhante à de outras populações, com a artéria de Adamkiewicz originando-se mais comumente no lado esquerdo, entre a 8a e a 12a vértebras torácicas (T8-T12).


Subject(s)
Humans , Male , Female , Paraplegia , Arteries/pathology , Spinal Cord , Angiography/methods , Multidetector Computed Tomography
SELECTION OF CITATIONS
SEARCH DETAIL